Novia FR - Fire Class B Roof and Wall Breather Membrane - 1.5m x 50m Roll
Novia FR - Fire Class B Roof and Wall Breather Membrane - 1.5m x 50m Roll
Guide Price: £134.03 (£160.84 inc VAT)
Price per m2: £1.79/m2 (£2.14 inc VAT)
- Product Code: A1-3559
- Delivery Time: 1 - 2 days
- Brand: Novia (Tech. support: 01622678952)
- Model and Size: 1.5m x 50m - 75m2
- Weight: 8.50kg
Our ratings on 23-12-2024:
4.7 out of 5 - Excellent
4.8 out of 5
Guide Price: £47.09
(£56.51 inc VAT)
Guide Price: £108.39
(£130.07 inc VAT)
Guide Price: £176.76
(£212.11 inc VAT)
Novia FR - Fire Class B Roof and Wall Breather Membrane - 1.5m x 50m Roll
Width: 1500mm
Length: 50000mm
Roll Coverage: 75m2
Weight/m2: 0.11kg
Weight: 8.5kg
Fire Rating (Reaction to Fire): B(Class 0)
Novia FR Roof and Wall Breather Membrane is a versatile, low cost fire class B-s1,d0 breather membrane for use in all pitched cold and warm roofs, and insulated wall applications, allowed for high rise buildings. The Novia FR Roof and Wall Breather membrane is made from 2-layer TPU which provides significantly improved UV performance. It has an excellent W1 water resistance while providing high breathability. The membrane is coloured black on the front side and white on the other side, with a clearly marked 150mm overlap line on the front. It is a breathable and vapour permeable membrane in one.
CHARACTERISTICS
CERTIFICATION
- Class B-s1,d0 fire rated when fitted to A1/A2 materials,
- Single product for all roofs and walls,
- Suitable for high-rise buildings,
- Made from 2-layer TPU,
- Significantly improved UV performance,
- Meets EN 13859-1 for roofs and EN 13859-2 for walls.
- For pitched cold and warm roofs,
- For insulated wall applications.
INSTALLATION
To walls
- Ensure upper layers overlap lower layers.
- Work from the bottom moving upwards and ensuring there are minimum overlaps of 100 mm on the horizontal joints.
- Do not begin a vertical lap joint within 300 mm of a corner,
- Vertical laps should be at least 150 mm.
- Ensure the bottom timber is also protected by an overlap.
- Fix at suitable intervals with galvanised nails, stainless staples or similar permanent fixings.
To roofs
- Ensure upper layers overlap lower layers.
- Work from the bottom moving upwards and ensure there are minimum overlaps.
- The membrane should be overlapped 200 mm on each side of the ridge.
- All vertical overlaps must be situated on a rafter and must be sealed.
- Fix at suitable intervals with galvanised nails, stainless staples or similar permanent fixings.
- At any entry points for services (soil pipes, vents etc.), ensure that the membrane is properly sealed.
- Use of Novia breather membrane tapes.
- Ensure that for wall or warm roof applications, a vapour barrier is installed on the warm side of the insulation.
Note:
Do not leave the membrane unnecessarily exposed to weathering, high winds, excessive UV etc. as this may cause damage over time. If you must leave the membrane exposed for extended periods of time, consider the use of suitable temporary protection materials.
CERTIFICATION
- CE marked,
- Meets EN 13859-1 for roofs and EN 13859-2 for walls.