British Gypsum Gypframe 99 FC 50 Fixing Channel (pack of 10)
British Gypsum Gypframe 99 FC 50 Fixing Channel (pack of 10)
Price: £122.89 (£147.47 inc VAT)
3 or more £119.78 (£143.74 inc VAT)
4 or more £116.64 (£139.97 inc VAT)
5 or more £113.51 (£136.21 inc VAT)
- Product Code: A1-818
- Delivery Time: 2 - 3 working days
- Brand: British Gypsum (Tech. support: 01159456123)
- Model and Size: 99 FC 50 - 2.4 m
- Weight: 40.04kg
Our ratings on 22-12-2024:
4.7 out of 5 - Excellent
4.8 out of 5
British Gypsum Gypframe 99 FC 50 Fixing Channel (pack of 10)
Thickness: 0.5mm
Width: 99mm
Length: 2400mm
Weight: 40.04kg
British Gypsum Gypframe 99 FC 50 Fixing Channel has a very wide application, but especially compatible for cross-bracing in medium weight fittings in twin frame wall systems, in accordance to BS 5234.
The channel can be used in variety of different systems, including:
- FireWall provides up to 240 minutes of fire resistance, while requiring minimal wall thickness, especially designed to meet the requirements of insurance companies in the words of fire protection, why it is especially applicable to warehouses, plant rooms and data storages. Special care should be given to any insulation system installed in order of preventing it to anyhow affect the performance of the system, which also goes for any openings is the wall which are generally not required with the FireWall system. Finally, it is advisable that a damp proof membranes are installed if dealing with a new concrete screeded floor;
- GypLyner IWL, providing fire protection and fire resistance, used for upgrading both thermal and sound performance of masonry walls, designed to correspond to BS 5234 standards. The system can increase the sound and thermal insulation of both new or existing walls, only if the elements are well fitted to the background, junctions properly sealed and water penetration and damp issues taken care of by applying recommended measures;
- GypLyner UNIVERSAL wall lining can be made to meet various requirements, both thermal and acoustic, especially applicable in refurbishment projects where the quality of the surface needs to be improved and the cavity accommodated to certain services such as water pipes. In order of meeting the requirements set by the applicable Building Regulations, proper cavity barriers should be installed and in order of improving the thermal performance of the surface, the cavity needs to be tightly sealed;
- GypWall AUDIO is a system especially designed to provide high sound performance, why is often used in cinemas, theatres and music rooms, also providing a certain level of fire resistance (up to 120 minutes) capable to offer protection to structural steel within the cavity, yet very lightweight in comparison to the alternatives;
- GypWall CLASSIC is a lightweight system which provides a 30-120 minutes of fire resistance, has substantial sound insulation performance, also protecting the metal framework from warping, rotting and twisting. The system can be have a number of different applications only if the position of the fixings and the installation are pre-planed and determined;
- GypWall EXTREME is a hybrid system consisting of Gyproc plasterboards, Gypframe metal products and Rigidur H fibre reinforced gypsum boards providing great sound insulation performance, great resistance and durability but also highly cost-effective due to the reduced maintenance cycle costs. The systems characteristics make it applicable to traffic corridors and student accommodations. It is recommended for control joints to be installed in order of reducing the construction stresses caused by contraction and expansion;
- GypWall QUIET is used for sound insulation of residential dwellings (mostly used in apartments and flats), is in accordance with the Approved Document E of the Building Regulations and the BS 5234 standard. It is recommended that the closure of the cavities is provided with mineral wool;
- GypWall QUIET IWL is in compliance with the Robust details constructions, meaning that there is no pre-completed testing required, also designed to meet BS 5234 requirements, used to accommodate services between the twin stud frameworks;
- GypWall QUIET SF whose considerable acoustic performance makes it applicable to separating walls (between apartments, for example), also providing fire resistance of 60-120 minutes. For optimal acoustic performance, it is recommended that all air paths are properly sealed;
- GypWall RAPID dB PLUS internal wall system incorporating Gyproc SoundBloc RAPID linings, providing not only acoustic insulation but also impact and fire resistance, in accordance with the applicable Building Regulations. The system includes two installation options with noggins (900mm stud framing) and without noggins (450mm stud frames) which are both very easy to install, achieving the Rw value of 40dB. The system is particularly applicable to internal wall constructions in residential dwellings, whereas special attention should be given to determining the position of services in the frame erection stage and the potential loss of acoustic insulation performance of the system through structural steelwork;
- GypWall ROBUST is available in there stud options (70mm, 92mm and 146mm), meeting BS 5234 requirements, great sound insulation and 60 minutes of fire resistance, and all in a single layer. Due to the durability it provides, it can be applied to almost any commercial building. Some constructions may include installing control joints in the partition, coinciding with movement joists, all in order of relieving the construction of stresses caused by contraction and expansion;
- GypWall STAGGERED has a wide application in both commercial and residential buildings such as hospitals, schools, offices, shops etc all due to increased sound insulation properties at a minimal partition width, in conformity with the BS 5234 and providing up to 90 minutes of fire resistance. When installing, it is important that the linings are not separated by a bridge created from the fixtures and services;
- ShaftWall is a lightweight system which can be installed in the early construction phase, especially applicable to areas with limited access, providing a fire-protective structure for the inner elements. It is designed to meet air pressure and deflection requirements, but also the boundary requirements prescribed by the applicable Approved Document B of the Building Regulations. The system can be found in stairwells, service ducts and risers and lift shafts, providing a protective enclosure.
APPLICATION
Gypframe 99 FC 50 Fixing Channel is used for cross-bracing medium weight fixtures and frame wall systems.
CERTIFICATION
The product is in compliance with the:
- British Standard BS 5234
- European Standard EN 14195