ARC T-Barrier Foundation for 100mm Party Wall Cavity - Fire Barrier for Party Wall Junctions at Foundation Level - Pack of 12

ARC T-Barrier Foundation for 100mm Party Wall Cavity - Fire Barrier for Party Wall Junctions at Foundation Level - Pack of 12
- Product Code: A1-5593
- Delivery Time: 2 - 3 working days
- Brand: ARC Building Solutions
- Model and Size: TBM100/100GW
Our ratings on 23-04-2025:

4.7 out of 5 - Excellent


4.8 out of 5
ARC T-Barrier Foundation for 100mm Party Wall Cavity - Fire Barrier for Party Wall Junctions at Foundation Level - Pack of 12
Thickness: 100mm
Width: 250mm
Length: 600mm
Pack Quantity: 12
Fire Protection (Resistance to Fire): 240minutes
ARC T-Barrier Foundation for 100mm Party Wall Cavity is a non-combustible rockfibre mineral wool cavity fire barrier that enables the closing of an external cavity at party wall junctions at foundation level receiving up to 4 hours fire integrity. ARC T-Barrier can be installed as the masonry work progresses, requiring only a friction fit within the cavity. Accuracy of masonry work is essential to ensure no gaps exist around the barrier. ARC T-Barrier is used where building regulations require the use of a mineral wool closer for acoustic insulation purposes. It provides an effective edge seal around the party wall cavity, helping to achieve a zero U-value.
Dimensions: a/b x c/d x length: 110mm/100mm x 105mm/250mm x 600mm
CHARACTERISTICS
- Easy to install,
- Friction fits,
- Seals edge of party wall cavity
- Up to 4 hours fire integrity,
- Highly effective as an edge seal than conventional systems,
- Zero U-value at party wall can be achieved,
- Reduces flanking noise,
- Minimises thermal bypass.
- ARC T-Barrier can be installed as the masonry work progresses, requiring only a friction fit within the cavity.
- Accuracy of masonry work is essential to ensure no gaps exist around the barrier.
Brand: ARC Building Solutions
Model and Size: CSS170
Delivery Time: 2 - 3 working days
180mm x 150mm x 1200mm ARC Cavity Stop Sock for 170mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Brand: ARC Building Solutions
Model and Size: OSCB25 - 75mm x 100mm x 1200mm
Delivery Time: 2 - 3 working days
100mm wide ARC OSCB25 is a non-combustible rockfibre mineral wool cavity barrier for installation where ventilation is required in service use. It has a 4mm thick reactive intumescent layer, which will rapidly expand when exposed to heat in a fire event, closing off the air gap and preventing v..
Brand: ARC Building Solutions
Model and Size: for 100mm cavity - 115mm x 120mm x 1200mm
Delivery Time: 2 - 3 working days
115mm x 120mm x 1200mm ARC TCB for 100mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party timber frame walls. It is ideally suited for providing a cavity fire barrier within the external w..
Brand: ARC Building Solutions
Model and Size: CSS185
Delivery Time: 2 - 3 working days
195mm x 150mm x 1200mm ARC Cavity Stop Sock for 185mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Brand: ARC Building Solutions
Model and Size: CSS125
Delivery Time: 2 - 3 working days
135mm x 120mm x 1200mm ARC Cavity Stop Sock for 125mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Brand: ARC Building Solutions
Model and Size: WTBR1250/200/50
Delivery Time: 2 - 3 working days
ARC Wired Tile Batten Barrier is a non-combustible wire reinforced rockfibre mineral wool fire barrier that stops fire between roof covering and underside of tiles. It is used as a fire, thermal and acoustic break at the party wall between the roof tiles and roof membrane. In conjunction with t..