ARC Cavity Stop Sock for 85mm Cavity - Fire Barrier 105mm x 100mm x 1200mm - Pack of 20

Length: 1200mm
Width: 105mm
Thickness: 100mm
Pack Quantity: 20
Fire Protection (Resistance to Fire): 240minutes
Cavity width: 85mm
Sleeve Colour: Green

105mm x 100mm x 1200mm ARC Cavity Stop Sock for 85mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the external wall cavity, in line with a separating wall or floor as specified in Approved Document B, and for closing the cavity at eaves level. ARC Cavity Stop Sock is simply compression fitted as the masonry work progresses. No mechanical fixing is required as the compression fit would hold the barrier in place, as the relevant Cavity Stop Sock is wider than the given cavity.

  

Note: The cavity width must be accurate and the cavity insulation should be cut back where the barrier will be located. Do not remove the cover. All corners and joints must be tightly butt jointed. Cavity Stop Sock barriers should not be bent around corners. Excess polythene should be removed, so Cavity Stop Sock can be tightly butt jointed.


CHARACTERISTICS
  • Up to 4 hours fire integrity,
  • Can be installed horizontally and vertically,
  • Easily installed with compression fit,
  • No mechanical fix is required,
  • Specified in terraced, semi-detached, apartments and major projects,
  • Meets requirements of Robust Detail Part E and Approved Document B.
INSTALLATION
  • The ARC Cavity Stop Sock must fully fill the cavity from external brick to internal block.
  • Any cavity insulation must be cut back at the location of the barrier.
  • Care must be taken to ensure that the built cavity width is accurate.
  • Use appropriate ARC Cavity Stop Sock for the given cavity width.
  • At the end of a run, or at a corner, lengths of barrier should be cut to the required length, and then tightly butt jointed ensuring no gaps remain.
Vertical application
  • Build up the internal masonry work first.
  • Then progress several courses of brickwork, before installing the barrier.
  • The brickwork can continue, building the barrier in.
  • Care must be taken to ensure the correct compression fit is achieved.
Horizontal application
  • Build the brickwork up to the level the barrier will be installed, ensuring the width of the cavity is correct.
  • Allow the brickwork to set, before push fitting the barrier in to place and under the correct compression.
CERTIFICATION


Brand: ARC Building Solutions Model and Size: CSS195
Delivery Time: 2 - 3 working days
205mm x 150mm x 1200mm ARC Cavity Stop Sock for 195mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Get Best Price
Brand: ARC Building Solutions Model and Size: CSS105
Delivery Time: 2 - 3 working days
120mm x 120mm x 1200mm ARC Cavity Stop Sock for 105mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Get Best Price
Brand: ARC Building Solutions Model and Size: SSL100/600/500 - 2.4m2
Delivery Time: 2 - 3 working days
ARC Soffit Slab is a non-combustible foil faced rockfibre mineral wool fire barrier used to fill the void within the soffit at the party wall location to stop fire spreading. In conjunction with the ARC Party Wall System would create a complete fire break at the separating wall between two dwel..
Get Best Price
Brand: ARC Building Solutions Model and Size: TBTF100/100
Delivery Time: 2 - 3 working days
ARC T-Barrier Timber Frame for 100mm Masonry Party Wall Cavity is a non-combustible rockfibre mineral wool cavity fire barrier that enables the closing of an external cavity at timber frame party wall junctions receiving up to one hour fire integrity. ARC T-Barrier can be installed as the ..
Get Best Price
Brand: ARC Building Solutions Model and Size: CSS85
Delivery Time: 2 - 3 working days
105mm x 100mm x 1200mm ARC Cavity Stop Sock for 85mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ext..
Get Best Price
Brand: ARC Building Solutions Model and Size: CSS225
Delivery Time: 2 - 3 working days
235mm x 200mm x 1200mm ARC Cavity Stop Sock for 225mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Get Best Price
This product is listed in the following categories and systems (click to show).