Menu
Menu
Your Cart

ARC Cavity Stop Sock for 225mm Cavity - Fire Barrier 235mm x 200mm x 1200mm - Pack of 3

ARC Cavity Stop Sock for 225mm Cavity - Fire Barrier 235mm x 200mm x 1200mm - Pack of 3
ARC Cavity Stop Sock for 225mm Cavity - Fire Barrier 235mm x 200mm x 1200mm - Pack of 3
  • Product Code: A1-6027
  • Delivery Time: 2 - 3 working days
  • Brand: ARC Building Solutions
  • Model and Size: CSS225
Our ratings on 01-04-2025:
TrustPilot Review 4.7
4.7 out of 5 - Excellent
Google My Business Reviews
4.8 out of 5
Show Other sizes

ARC Cavity Stop Sock for 225mm Cavity - Fire Barrier 235mm x 200mm x 1200mm - Pack of 3

Length: 1200mm
Width: 235mm
Thickness: 200mm
Pack Quantity: 3
Fire Protection (Resistance to Fire): 120minutes
Cavity width: 225mm
Sleeve Colour: Black

235mm x 200mm x 1200mm ARC Cavity Stop Sock for 225mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the external wall cavity, in line with a separating wall or floor as specified in Approved Document B, and for closing the cavity at eaves level. ARC Cavity Stop Sock is simply compression fitted as the masonry work progresses. No mechanical fixing is required as the compression fit would hold the barrier in place, as the relevant Cavity Stop Sock is wider than the given cavity.

  

Note: The cavity width must be accurate and the cavity insulation should be cut back where the barrier will be located. Do not remove the cover. All corners and joints must be tightly butt jointed. Cavity Stop Sock barriers should not be bent around corners. Excess polythene should be removed, so Cavity Stop Sock can be tightly butt jointed.


CHARACTERISTICS
  • Up to 4 hours fire integrity,
  • Can be installed horizontally and vertically,
  • Easily installed with compression fit,
  • No mechanical fix is required,
  • Specified in terraced, semi-detached, apartments and major projects,
  • Meets requirements of Robust Detail Part E and Approved Document B.
INSTALLATION
  • The ARC Cavity Stop Sock must fully fill the cavity from external brick to internal block.
  • Any cavity insulation must be cut back at the location of the barrier.
  • Care must be taken to ensure that the built cavity width is accurate.
  • Use appropriate ARC Cavity Stop Sock for the given cavity width.
  • At the end of a run, or at a corner, lengths of barrier should be cut to the required length, and then tightly butt jointed ensuring no gaps remain.
Vertical application
  • Build up the internal masonry work first.
  • Then progress several courses of brickwork, before installing the barrier.
  • The brickwork can continue, building the barrier in.
  • Care must be taken to ensure the correct compression fit is achieved.
Horizontal application
  • Build the brickwork up to the level the barrier will be installed, ensuring the width of the cavity is correct.
  • Allow the brickwork to set, before push fitting the barrier in to place and under the correct compression.
CERTIFICATION


Brand: ARC Building Solutions Model and Size: OSCB25 - 75mm x 100mm x 1200mm
Delivery Time: 2 - 3 working days
100mm wide ARC OSCB25 is a non-combustible rockfibre mineral wool cavity barrier for installation where ventilation is required in service use. It has a 4mm thick reactive intumescent layer, which will rapidly expand when exposed to heat in a fire event, closing off the air gap and preventing v..
Get Best Price
Brand: ARC Building Solutions Model and Size: TBTF100/100
Delivery Time: 2 - 3 working days
ARC T-Barrier Timber Frame for 100mm Masonry Party Wall Cavity is a non-combustible rockfibre mineral wool cavity fire barrier that enables the closing of an external cavity at timber frame party wall junctions receiving up to one hour fire integrity. ARC T-Barrier can be installed as the ..
Get Best Price
Brand: ARC Building Solutions Model and Size: for 100mm Cavity - 115mm x 500mm x 500mm
Delivery Time: 2 - 3 working days
ARC TCB Square is a faster and easier to install cavity barrier around service penetrations in external timber frame walls of low rise houses. It exceeds the Building Regulation part B fire safety norm EI30/15. ARC TCB Square provides a more robust solution, compared with either boxing in using cut ..
Get Best Price
Brand: ARC Building Solutions Model and Size: CSS110
Delivery Time: 2 - 3 working days
120mm x 120mm x 1200mm ARC Cavity Stop Sock for 110mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Get Best Price
Brand: ARC Building Solutions Model and Size: CSS90
Delivery Time: 2 - 3 working days
110mm x 100mm x 1200mm ARC Cavity Stop Sock for 90mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ext..
Get Best Price
Brand: ARC Building Solutions Model and Size: CSS300
Delivery Time: 2 - 3 working days
310mm x 200mm x 1200mm ARC Cavity Stop Sock for 300mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Get Best Price
This product is listed in the following categories and systems (click to show).