Menu
Menu
Your Cart

ARC Cavity Stop Sock for 145mm Cavity - Fire Barrier 155mm x 120mm x 1200mm - Pack of 15

ARC Cavity Stop Sock for 145mm Cavity - Fire Barrier 155mm x 120mm x 1200mm - Pack of 15
ARC Cavity Stop Sock for 145mm Cavity - Fire Barrier 155mm x 120mm x 1200mm - Pack of 15
  • Product Code: A1-6015
  • Delivery Time: 2 - 3 working days
  • Brand: ARC Building Solutions
  • Model and Size: CSS145
Our ratings on 27-02-2025:
TrustPilot Review 4.7
4.7 out of 5 - Excellent
Google My Business Reviews
4.8 out of 5
Show Other sizes

ARC Cavity Stop Sock for 145mm Cavity - Fire Barrier 155mm x 120mm x 1200mm - Pack of 15

Length: 1200mm
Width: 155mm
Thickness: 120mm
Pack Quantity: 15
Fire Protection (Resistance to Fire): 240minutes
Cavity width: 145mm
Sleeve Colour: Light Blue

155mm x 120mm x 1200mm ARC Cavity Stop Sock for 145mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the external wall cavity, in line with a separating wall or floor as specified in Approved Document B, and for closing the cavity at eaves level. ARC Cavity Stop Sock is simply compression fitted as the masonry work progresses. No mechanical fixing is required as the compression fit would hold the barrier in place, as the relevant Cavity Stop Sock is wider than the given cavity.

  

Note: The cavity width must be accurate and the cavity insulation should be cut back where the barrier will be located. Do not remove the cover. All corners and joints must be tightly butt jointed. Cavity Stop Sock barriers should not be bent around corners. Excess polythene should be removed, so Cavity Stop Sock can be tightly butt jointed.


CHARACTERISTICS
  • Up to 4 hours fire integrity,
  • Can be installed horizontally and vertically,
  • Easily installed with compression fit,
  • No mechanical fix is required,
  • Specified in terraced, semi-detached, apartments and major projects,
  • Meets requirements of Robust Detail Part E and Approved Document B.
INSTALLATION
  • The ARC Cavity Stop Sock must fully fill the cavity from external brick to internal block.
  • Any cavity insulation must be cut back at the location of the barrier.
  • Care must be taken to ensure that the built cavity width is accurate.
  • Use appropriate ARC Cavity Stop Sock for the given cavity width.
  • At the end of a run, or at a corner, lengths of barrier should be cut to the required length, and then tightly butt jointed ensuring no gaps remain.
Vertical application
  • Build up the internal masonry work first.
  • Then progress several courses of brickwork, before installing the barrier.
  • The brickwork can continue, building the barrier in.
  • Care must be taken to ensure the correct compression fit is achieved.
Horizontal application
  • Build the brickwork up to the level the barrier will be installed, ensuring the width of the cavity is correct.
  • Allow the brickwork to set, before push fitting the barrier in to place and under the correct compression.
CERTIFICATION


Brand: ARC Building Solutions Model and Size: CSS185
Delivery Time: 2 - 3 working days
195mm x 150mm x 1200mm ARC Cavity Stop Sock for 185mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Get Best Price
Brand: ARC Building Solutions Model and Size: CSS180
Delivery Time: 2 - 3 working days
190mm x 150mm x 1200mm ARC Cavity Stop Sock for 180mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Get Best Price
Brand: ARC Building Solutions Model and Size: TBR100/25
Delivery Time: 2 - 3 working days
ARC T-Barrier Pitched Roof for 100mm Masonry Party Wall Cavity is a non-combustible rockfibre mineral wool cavity fire barrier that stops fire between party wall and roof covering. ARC T-Barrier Pitched Roof is designed to provide a fire, thermal and acoustic barrier between the top of the party wal..
Get Best Price
Brand: ARC Building Solutions Model and Size: WTBR1250/200/50
Delivery Time: 2 - 3 working days
ARC Wired Tile Batten Barrier is a non-combustible wire reinforced rockfibre mineral wool fire barrier that stops fire between roof covering and underside of tiles. It is used as a fire, thermal and acoustic break at the party wall between the roof tiles and roof membrane. In conjunction with t..
Get Best Price
Brand: ARC Building Solutions Model and Size: CSS275
Delivery Time: 2 - 3 working days
285mm x 200mm x 1200mm ARC Cavity Stop Sock for 275mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Get Best Price
Brand: ARC Building Solutions Model and Size: CSS135
Delivery Time: 2 - 3 working days
145mm x 120mm x 1200mm ARC Cavity Stop Sock for 135mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Get Best Price
This product is listed in the following categories and systems (click to show).