Menu
Your Cart

34mm JCW Acoustic Deck 34 - Cement Particle Board based Acoustic Overlay Board

34mm JCW Acoustic Deck 34 -  Cement Particle Board based Acoustic Overlay Board
Guide Price
34mm JCW Acoustic Deck 34 - Cement Particle Board based Acoustic Overlay Board
Guide Price: £56.75 (£68.10 inc VAT)
100 or more £51.59 (£61.91 inc VAT)
150 or more £47.30 (£56.76 inc VAT)
200 or more £43.67 (£52.40 inc VAT)
  • Product Code: A1-1965
  • Delivery Time: 2 - 3 working days
  • Brand: JCW
  • (Tech. support: 08453402858)
  • Model and Size: 1200x600mm - 0.72m2
  • Weight: 23.00kg
Our ratings on 02-07-2024:
TrustPilot Review 4.7
4.7 out of 5 - Excellent
Google My Business Reviews
4.8 out of 5

34mm JCW Acoustic Deck 34 - Cement Particle Board based Acoustic Overlay Board

Width: 600mm
Length: 1200mm
Board Coverage: 0.72m2
Density: 94kg/m3
Weight/m2: 31.9kg
Weight: 23kg

34mm JCW Acoustic Deck 34 is a premium quality overlay board with a 12mm resilient acoustic layer laminated to a 22mm T&G cement particle board. The slim profile and high acoustic performance makes it ideal for timber floor refurbishment projects. Acoustic Deck 34 is ideal for overlaying directly to an existing sub-floor.

CHARACTERISTICS
  • An ideal solution where construction heights are a problem,
  • Easy to install,
  • Suitable for for new flooring systems or upgrades to existing separating floors,
  • An economical product for Conversion projects
  • Offers good impact sound improvement,
  • Deck ready for final floor finish e.g.laminates, carpets and carpet tiles,
  • Overlaid onto flat timber floors.



APPLICATION
  • New build
  • Refurbishments
  • Domestic upgrade
  • On concrete and timber floors
INSTALLATION
  • JCW Acoustic Deck 34 boards are best laid towards the end of the project to protect from general trades, high floor loading and moisture leading to expansion.
  • The boards must be dry and acclimatised at least 24 hours prior to installation, this will minimise any expansion or contraction after installation.
  • When using JCW Acoustic Deck 34 as a structural board, it must be laid on to flat or levelled joists in the opposite direction of the joists.
  • Use tungsten carbide tipped blades for cutting at all times. Particle Board can be drilled using conventional portable drilling machines. It is a wood and cement panel, therefore does not require percussion drilling. It can be sanded using a vibrating sanding machine or belt sanding machine.
  • Ensure that the floor surface is flat, dry, and free from all debris and that the wall surfaces are prepared - plaster skimmed or plaster boarded down to the level of the sub-deck. There shouldn't be any gaps at wall edges.
  • Apply 5mm foam flat wall JCW Perimeter Edging Strip or L shaped strips to the base of all perimeter walls allowing approximately 15mm excess foam above the finished acoustic board height. This can later be folded down on top of the acoustic floor surface to isolate the skirting boards.
  • Remove any tongues at the wall edges, then cut & scribe the first corner board into place and butt up to the Edging Strip. Do not compress the JCW Perimeter Edging Strip.
  • Ensure all T&G board joints must be fully adhesive bonded using a recommended adhesive.
  • Proceed with the second and successive rows ensuring that all board joints are staggered. The last row of boards will require accurate cutting & scribing to butt up to the wall.
  • Any minor gaps between the JCW Perimeter Edging Strip and the acoustic board must be filled with JCW Acoustic Sealant/Mastic.
  • It is imperative that the JCW Perimeter Edging Strip is not compressed in order to maintain acoustic isolation and an allowance for expansion.
  • At the door threshold leave a 5mm gap between the adjoining acoustic boards and fill with JCW Acoustic Sealant. If the sub-floor at the doorways is not flat, the acoustic boards may require additional base support to reduce compressive joint movement. Additionally the surface joints could be sanded up to 5mm to level if required.
  • The finished floor should not be walked on for a period of up to 24 hours to allow the adhesive to cure undisturbed.
  • Ensure that the board joint adhesive has fully cured prior to overlaying any final floor covering.
CERTIFICATION

JCW Acoustic Deck 34 board has been independently tested in a UK Verified independent UKAS accredited laboratory.

12mm JCW ImpactaLay Acoustic Mat
Guide Price
Brand: JCW Model and Size: 1200x1000mm - 1.20m2
Delivery Time: 2 - 3 working days
12mm JCW ImpactaLay Acoustic Mat is a remarkably cost-effective and one of the quickest and most effective acoustic solutions on the market. It increases airborne sound insulation and reduces impact noise transmission so much that there is no need for the installation of false floors or false walls...
Guide Price: £36.31
£43.57 inc VAT
10mm JCW Impactalay 10 Acoustic Mat for Timber and Concrete Floors
Guide Price
Brand: JCW Model and Size: 1200x1000mm - 1.20m2
Delivery Time: 2 - 3 working days
10mm JCW Impactalay 10 Acoustic Mat is a remarkably cost-effective and one of the quickest and most effective acoustic solutions on the market. It increases airborne sound insulation and reduces impact noise transmission so much that there is no need for the installation of false floors or false wal..
Guide Price: £26.75
£32.10 inc VAT
JCW Fire and Acoustic Socket Box Inserts - Single x 47mm deep
Guide Price
Brand: JCW Model and Size: Single x 47mm deep
Delivery Time: 2 - 3 working days
Single x 47mm deep JCW Fire and Acoustic Socket Box Insert is an acoustic insulation system for wall sockets to eliminate the transfer of sound through walls. Suitable for both new installations and refurbishments, available for both single, double and twin-gang applications. Fabricated from Class O..
Guide Price: £3.80
£4.56 inc VAT
80mm JCW Acoustic Batten 80C
Guide Price
Brand: JCW Model and Size: 80x42x1800mm
Delivery Time: 5 - 7 days
JCW Acoustic Batten 80C is a 10mm pre bonded open cell, recycled polyurethane resilient layer to a 70mm timber batten for use on concrete subfloors. The JCW Acoustic Batten 80C offers an exceptional reduction in impact sound, whilst maintaining a high compression strength. They can be overlaid with ..
Guide Price: £6.97
£8.36 inc VAT
50mm JCW Noise Stopper Pad - 600mm x 600mm 50mm JCW Noise Stopper Pad - 600mm x 600mm
Guide Price
Brand: JCW Model and Size: 600x600mm - 0.36m2
Delivery Time: 3 - 5 days
50mm JCW Noise Stopper Pad is an aluminium non-flammable foil covered pad with 2 layers of non-flammable sound absorbing acoustic mineral wool with a mineral loaded sound barrier mat core layer. This sound blocking pad designed to be laid on top of suspended ceiling grid tiles in offices and rooms. ..
Guide Price: £9.40
£11.28 inc VAT
50mm JCW Noise Stopper Pad - 1200mm x 600mm 50mm JCW Noise Stopper Pad - 1200mm x 600mm
Guide Price
Brand: JCW Model and Size: 1200x600mm - 0.72m2
Delivery Time: 7 - 10 days
50mm JCW Noise Stopper Pad is an aluminium non-flammable foil covered pad with 2 layers of non-flammable sound absorbing acoustic mineral wool with a mineral loaded sound barrier mat core layer. This sound blocking pad designed to be laid on top of suspended ceiling grid tiles in offices and rooms. ..
Guide Price: £17.05
£20.46 inc VAT
This product is listed in the following categories and systems (click to show).