200mm x 8mm MLN Fire Rated Metal Fixings for Rainscreen Insulation in Ventilated Cladding Systems - pack of 50

200mm x 8mm MLN Fire Rated Metal Fixings for Rainscreen Insulation in Ventilated Cladding Systems - pack of 50
- Product Code: A1-4665
- Delivery Time: 5 - 7 days
- Brand: Klimas W-M
- Model and Size: 200mm x 8mm - 50 nos
Our ratings on 03-03-2025:

4.7 out of 5 - Excellent


4.8 out of 5
200mm x 8mm MLN Fire Rated Metal Fixings for Rainscreen Insulation in Ventilated Cladding Systems - pack of 50
Diameter: 8mm
Length: 200mm
Pack Quantity: 50
For insulation thickness: 140mm
200mm x 8mm Fire Rated MLN Metal Fixings for Rainscreen Insulation in Ventilated Cladding Systems for fixing mineral wool on concrete, aerated concrete, solid clay bricks and solid silicate bricks. Can be used with 140mm thick mineral wool insulation. Anchoring depth 50mm on hard substrate. Fire Rated MLN Metal Fixing have galvanised connector of high corrosion resistance.
CHARACTERISTICS
- Galvanised steel,
- Non-inflammable,
- high corrosion resistance.


- Maximum thickness of mineral wool: 140mm
- Maximum depth of insertion in hard substrate: 50mm
Brand: Klimas W-M
Model and Size: 50mm-
Delivery Time: 1 - 2 days
50mm Screwed-in Helical Fastener WK-DS is for fixing lightweight non-structural components (max. 5 kg/piece) on polystyrene insulation, for example, fixing elements such as signboards, building numbers, mailboxes, lighting fixtures, motion sensors, etc. They are made from high-quality polyamide and ..
£6.50
£7.80 inc VAT
Brand: Klimas W-M
Model and Size: 200mm x 8mm - 50 nos
Delivery Time: 5 - 7 days
200mm x 8mm Fire Rated MLN Metal Fixings for Rainscreen Insulation in Ventilated Cladding Systems for fixing mineral wool on concrete, aerated concrete, solid clay bricks and solid silicate bricks. Can be used with 140mm thick mineral wool insulation. Anchoring depth 50mm on hard substrate. Fir..
Brand: Klimas W-M
Model and Size: 180mm
Delivery Time: In Stock 1-2 working days
180mm Universal Insulation Panel Fixing with Metal Pin LMX10 is for fixing 120mm thick polystyrene, mineral wool and phenolic external insulation on concrete, brick, light and autoclave concrete substrates. The anchor is made of polypropylene and is impact resistant. The expander pin is made of zinc..
£60.80
£72.96 inc VAT
Brand: Klimas W-M
Model and Size: 260mm
Delivery Time: 1 - 2 days
260mm Universal Insulation Panel Fixing with Metal Pin LMX10 is for fixing 200mm thick polystyrene, mineral wool and phenolic external insulation on concrete, brick, light and autoclave concrete substrates. The anchor is made of polypropylene and is impact resistant. The expander pin is made of zinc..
Brand: Klimas W-M
Model and Size: 170mm x 8mm - 50 nos
Delivery Time: 5 - 7 days
170mm x 8mm Fire Rated MLN Metal Fixings for Rainscreen Insulation in Ventilated Cladding Systems for fixing mineral wool on concrete, aerated concrete, solid clay bricks and solid silicate bricks. Can be used with 110mm thick mineral wool insulation. Anchoring depth 50mm on hard substrate. Fir..
Brand: Klimas W-M
Model and Size: Grey - 67mm
Delivery Time: 1 - 2 days
67mm Grey Polystyrene Plug KSG for EWI Polystyrene Sheets used to cover the pin shaft, blocking the thermal bridge giving a homogeneous surface.INSTALLATIONThe hole must be then covered with the grey polystyrene plug to stop any thermal bridging (last picture).CERTIFICATIONEuropean Technical Approva..
£8.06