121-130mm Cavity Stop Sock GDS100 (pack of 12) - GIS DUO Cavity Stop
121-130mm Cavity Stop Sock GDS100 (pack of 12) - GIS DUO Cavity Stop
Guide Price: £81.56 (£97.87 inc VAT)
- Product Code: A1-5818
- Delivery Time: 2 - 3 working days
- Brand: Guardian Insulation Solutions (Tech. support: : 01827219327)
- Model and Size: 121-130mm
Our ratings on 23-12-2024:
4.7 out of 5 - Excellent
4.8 out of 5
121-130mm Cavity Stop Sock GDS100 (pack of 12) - GIS DUO Cavity Stop
Length: 1200mm
Height: 130mm
Pack Quantity: 12
Pack coverage: 0m2
Thermal Conductivity: 0.037W/mK
Fire Rating (Reaction to Fire): A1(Non-combustible)
Fire Protection (Resistance to Fire): 240minutes
121-130mm Cavity Stop Sock GDS100 - GIS DUO Cavity Stops are designed to prevent the spread of flames and smoke along the cavity and provides up to 4 hours fire integrity. They are 1200mm mineral wool slabs that are encapsulated in recycled plastic. This plastic will not add to the propagation of a fire. Cavity Stop Socks GDS100 also prevent of flanking noise transmission, along external and separating wall cavities. It can be used horizontally and vertically in both brick/block and brick/timber-frame applications.
Note: Other sizes are available on request
CHARACTERISTICS
- Easy to install,
- Resists the passage of fire and smoke,
- Resists the passage of sound,
- 4 hour fire integrity.
APPLICATION
Cavity Stop Sock GDS100 is used horizontally and vertically in both brick/block and brick/timber-frame applications.
INSTALLATION
- Cavity Stop Sock GDS100 Should be compression fitted.
- Ensure all butt joints are tightly fitted.
- The Stop Sock must fill the cavity from the rear of the outer leaf to the face of the inner leaf.
- In brick to block or brick to brick, the Stop Socks are fitted as the structure is built.
- In a timber-frame application the flanges must be fixed to the timber frame using a large clout head nail or staple at a minimum of 150mm centres.
- When in a vertical application both flanges must be fixed at 150mm centres alternatively.
- Around door and window openings the horizontal barrier should always overlap the vertical barrier.
CERTIFICATION
- BS EN 13501-1, BS EN1366-4, BS476: Part 20