100mm Unilin FR-BGM Flat Roof Insulation Board (pack of 5)
100mm Unilin FR-BGM Flat Roof Insulation Board (pack of 5)
Guide Price: £94.56 (£113.47 inc VAT)
Price per m2: £26.27/m2 (£31.52 inc VAT)
- Product Code: A1-4925
- Delivery Time: 3 - 5 days
- Brand: Unilin (prev. Xtratherm)
- Model and Size: 1200x600mm - 3.6m2
- Weight: 11.52kg
Our ratings on 21-11-2024:
4.7 out of 5 - Excellent
4.8 out of 5
100mm Unilin FR-BGM Flat Roof Insulation Board (pack of 5)
Length: 1200mm
Width: 600mm
Thickness: 100mm
Pack Quantity: 5
Board Coverage: 0.72m2
Pack Coverage: 3.6m2
Density: 32kg/m3
Weight/m2: 3.2kg
Weight: 11.52kg
Thermal Conductivity: 0.025W/mK
R-Value: 3.75m2K/W
Compressive Strength: 150kPa
100mm Unilin FR-BGM is a a BBA certified high performance PIR insulation board that is faced with a fleece finished bitumen/glass facers and is suitable for use below partially bonded bitumen based built up roofing systems. Unilin FR-BGM is suitable to apply torch on felt directly on the insulation. FR-BGM can also be used in mechanically fastened or loose laid ballasted bituminous roofing systems. Unilin FR/BGM is suitable for use on roof decks that are subject to limited maintenance foot traffic.
Note: This high performance roof insulation board was formerly known as 100mm Flat Roof Insulation Board Xtratherm FR-BGM
CHARACTERISTICS- High Performance Rigid Insulation,
- Compatible with Most bituminous based Roofing Systems,
- Non-deleterious Material,
- Manufactured without the use of CFCs/HCFCs,
- Zero ODP and Low GWP,
- Suitable for New Build and Refurbishment Projects,
- Fleece finished bitumen/glass fibre facings,
- Suitable for bonding with approved bitumen adhesive systems
- Bitumen based built up roofing systems,
- Suitable to apply torch on felt directly on the insulation,
- On roof decks that are subject to limited maintenance foot traffic,
- Flat and tapered roofs.
- The construction should be protected from rain penetration during breaks in the process,
- Ensure that the construction remains free from moisture,
- Ensure that the roof is flat, so rainfall does not pond,
- Decks should be primed before the application of the hot bitumen used to bond the vapour control layer.
- On metal decks, Unilin FR/BGM should be laid break bonded into hot bitumen (max temperature 240C) mopped or poured over the vapour control layer. Ensure all edges of the boards are supported.
- On plywood decks, Unilin FR/BGM should be fully bedded in hot bitumen over a continuous vapour control layer which has been nailed or bonded to the deck. The boards can also be mechanically fixed, fixing heads should be sealed with bitumen.
- On concrete decks, ensure they are laid to provide correct falls to outlets and are clean, dry, without projections. Primer should be laid in accordance with the manufacturers instructions. The vapour control layer should be fully bonded to the deck and the Unilin FR/BGM should be laid into hot bitumen on the vapour control layer in a break bonded pattern. The boards can also be mechanically fixed.
- Unilin FR/BGM, (Fleece side upper most) may also be fully bonded. Guidance in regard to moisture and condensation should be in accordance with BS 8217: 2005 (Reinforced bitumen membranes for roofing).